Installing a Double-High, Double-Wide Gigabit-Backplane Physical Interface Module on the
SRX Series Services Gateway
CAUTION: Only SRX650 Services Gateway supports hot-swappable
functionality for GPIMs. Ensure that the GPIM is installed in the appropriate
GPIM slot. For more information about the appropriate GPIM slots, see “SRX
Series Services Gateway Gigabit-Backplane Physical Interface Modules
Overview” on page 5.
The SRX550 and SRX650 Services Gateway chassis can hold interface modules that
use four standard Gigabit-Backplane Physical Interface Module (GPIM) slots each. These
GPIMs must be installed in specific groups of four standard slots as shown in Table 12
on page 27.
NOTE: Installing a GPIM on the SRX550 Services Gateway is similar to
installing a GPIM on the SRX650 Services Gateway.
Table 12: Slot Groups for Double-High, Double-Wide GPIMs
Slot Groups for Double-High, Double-Wide GPIMsDevice
Top four standard slots (slots 5, 6, 7, and 8)SRX550
Bottom four standard slots (slots 1, 2, 3, and 4) and top four standard slots
(slots 5, 6, 7, and 8)
SRX650
Before installing the double-high, double-wide GPIM, you must first remove the center
GPIM guide-rail bracket:
1. Remove the four blank GPIM slot covers from the slots into which you will install the
double-high, double-wide GPIM.
2. Using a number 2 Phillips (+) screwdriver, remove the screw from the center GPIM
guide-rail bracket, as shown in Figure 12 on page 28, and remove the guide-rail bracket.
3. Store the guide-rail bracket for later use. The guide-rail bracket can be stored on the
rack-mount bracket, as shown in the callout in Figure 12 on page 28.