NOTE: To maintain proper airflow through the services gateway, leave blank
faceplates in place over slots that do not contain GPIMs. Do not remove a
blank faceplate unless you are installing a GPIM in the empty slot. If you need
to remove a blank faceplate to install the new GPIM into this slot, see
“Removing a Blank Gigabit-Backplane Physical Interface Module Faceplate
from the SRX Series Services Gateway” on page 24.
NOTE: Installing a GPIM on the SRX550 Services Gateway is similar to
installing a GPIM on the SRX650 Services Gateway.
To install a GPIM:
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis. For more information about ESD,
see “Preventing Electrostatic Discharge Damage to the SRX Series Services Gateway”
on page 23.
2. Grasp the handles on each side of the GPIM faceplate, and align the edges of the
GPIM circuit board with the guide rails at each side of the GPIM slot.
NOTE: If you are installing a double-high, double-wide GPIM such as the
24-Port Ethernet XPIM, you must remove the center GPIM slot bracket.
3. Slide the GPIM into the services gateway until it seats firmly in the device.
CAUTION: Slide the GPIM straight into the slot to avoid damaging the
components on the GPIM.
Figure 10: Installing a Double-High, Single-Wide GPIM in an SRX650
Services Gateway
650
g032731
4. Using a Phillips (+) screwdriver, tighten the captive screws on each side of the GPIM
faceplate.
25Copyright © 2012, Juniper Networks, Inc.
Chapter 2: Installing and Removing Interfaces on the SRX Series Services Gateway