c. Click OK to save changes, and click Commit to apply the configuration and other
pending changes (if any).
For more information, in the J-Web interface, select Configure>Interfaces and click Help.
Using the CLI
To perform basic configuration of the 1-Port VDSL2 (Annex A) Mini-PIM and to configure
network interfaces for the services gateway with the CLI:
Verify that the 1-Port VDSL2 interface is installed on the device:
show chassis hardware
Verify the status of the interface:
show interfaces terse
Assign the port an IP address:
set interfaces pt-1/0/0 unit 0 family inet address interface address/destination prefix
Add or select a security zone; for example, Zone1:
set security zones security-zone trust interfaces pt-1/0/0.0 host-inbound-traffic
system-services all
Add or select security zones for host inbound traffic options protocols:
set security zones security-zone trust interfaces pt-1/0/0.0 host-inbound-traffic protocols
all
Set security policies:
set security policies default-policy permit-all
See the Junos OS Network Interfaces Configuration Guide for more details.
Related
Documentation
1-Port VDSL2 (Annex A) Mini-Physical Interface Module Overview on page 89
1-Port VDSL2 (Annex A) Mini-Physical Interface Module Key Features on page 90
1-Port VDSL2 (Annex A) Mini-Physical Interface Module Supported Profiles on page 91
1-Port VDSL2 (Annex A) Mini-Physical Interface Module Hardware Specifications on
page 91
1-Port VDSL2 (Annex A) Mini-Physical Interface Module Cable Specifications on page 192
Copyright © 2012, Juniper Networks, Inc.94
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide
Vue de la page 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 263 264

Commentaires sur ces manuels

Pas de commentaire